USG offers professionals a complete set of architectural drawings for planning and estimation. Whether you need exterior design detail drawings or interior design detail drawings, make the most informed decisions with our comprehensive UL assemblies directory and UL assembly details. Planning your next project is easier than ever with USG’s ... 1.1.1. Provide firestopping and smoke seal systems as detailed on drawings and as specified herein. 1.1.2. This Section specifies material requirements for firestopping and smoke seal systems that are common to mechanical work Sections and it is a supplement to each Section and is to be read accordingly. 1.2.Intraarticular injection was performed under ul- ... AJR 2010; 194:1314; [web]W414–W419. 10. Kijowski R ... design of variable refocusing flip angle schedules.Design Select LED Area Luminaire. Lithonia Lighting. RSX1. Design Select ... 35 W49 W73 W52 W94 W96 W131 W153 W176 W217 W264 W285 W346 W419 W485 W586 W ... UL/CUL ...Design Studio Design Studio. Wall Assemblies; Floor-Ceiling Assemblies; Roof-Ceiling Assemblies; Design Details; Shaft Wall Limiting Heights & Spans; Competitor Comparison Tool; USG Sustainability Tool; USG Ceiling Technix™ Virtual Acoustics Experience™ (VAE) USG Assembly Builder™ All Design Studio

The Cavity Shaft Wall System includes components that provide the strength to withstand lateral loads and fire protection necessary for walls that enclose elevator shafts, stairwells and other vertical shafts. The system includes gypsum liner panels, gypsum panels and cement board, interior finishing products and framing components. Dec 30, 2565 BE ... Designing a Vaccine Construct. The vaccine construct design ... Amin-ul. Microbial Pathogenesis (2021), 155 ... 2015, 43 (W1), W419– W424, DOI: ...

Do you want to design a token economy? Start by having a goal that makes sense. Receive Stories from @albertocuestacanada Publish Your First Brand Story for FREE. Click Here.

Mecca is where Abraham built the Ka’aba, and some believe he did so in order to rebuild the Bait-ul-Allah that had originally been built by Adam. This is the building that every Mu...Partitions UL Design U305 ULC Design W301 (similar) Drywall System Studs: Wood 38 x 89 mm (2 X4 ) (nom.). Stud spacing: 400 mm (16 ) o.c. Gypsum panel: 15.9 mm (5/8 ) SHEETROCK Brand Gypsum Panel, FIRECODE Core, or 15.9 mm (5/8 ) SHEETROCK Brand Gypsum Panel, Water Resistant, FIRECODE Core, each side. Panel orientation: …Designers play an important part in any company. Whether they are working on product design, website design, brand creation, advertising banner or many more. A customer comes to kn...6 CGC Fire-Resistant Assemblies Test Certification Test Conditions and Fire and sound tested assemblies listed in this Selector are based on characteristics, properties and performance Certification of materials and systems obtained under controlled test conditions as set forth in the appropriate ULC and ASTM Standards in effect at the time of test. …

%PDF-1.5 %Çì ¢ 7 0 obj > stream xœí\[sݶ 挟ªf¦¹ØIÓé 'ã:bãà w ykeÉ’ÝʲeÙIÕ‡Ž#'êDv"{¦Ó¿Õ_Ø] $–$ ò kÒ—ŒF ‰ ì.€Ýo ...

UL design W419 – System A is similar to design U499 except that steel clips may be used to attach the furring channels to the studs. Clips are spaced a maximum of 24 in. OC and secured to studs with No. 8 x 1-1/2 in. minimum self-drilling S-12 steel screw through center grommet.

ULC Design Nos. U311, W406, W408, W419, W423, W440, W441, W442, W508, W600, Z500 UL Design Nos. U305, U311, U317, U411, U412, U448, U465, V417, V418, V419 Density Dimensions Thickness. ... (UL design no. V417 and U465) 1 hour (ULC W447) 1 Construction Description Transmission Loss. ROCKWOOL 8 160 250 400 630 1000 1600 …UL Evaluation Report - National GypsumUL Evaluation Report UL ER R3501-02 Issued: June 12, 2015 ..... Date post: 18-Mar-2020: Category: Documents: Upload: others View: 726 times: Download: 16 times: Download Report this document. Share this document with a friend. Embed Size (px ... National Gypsum Purple Book - Fire-Rated Assemblies in Commercial Construction - BuildSite. This pdf provides detailed information and illustrations of various fire-rated assemblies for walls, floors, ceilings and roofs using National Gypsum products. Learn how to select the best solutions for your projects and comply with building codes and standards. Jan 18, 2560 BE ... USG Design Studio | UL U419 Fire Resistant Assembly, Fire Rated Assembly, Fire Rated Detail http://www.usgdesignstudio.com/printassembly.asp ... Fiberglass Insulation. The smart choice to make spaces more comfortable and energy efficient. R-Value. The ability to resist heat flow — insulation's thermal resistance. Thermal Properties. Ability to provide thermal resistance for comfort and efficiency. Insulating for Sound. Sound absorption characteristics, helping reduce noise transmission. Use UL design W419 for 1- through 4-hour shaftwall systems or UL design V497 for 1- and 2-hour assemblies using Type X gypsum board on one side of minimum 3 ⅝" steel …UL Design I504. Use: Rated ceilings above corridors, mechanical rooms, or other incidental uses required by Section 509 of the IBC. 1 Hr. Horizontal Ceiling Membrane fire resistance rating. 3 layers of Gold Bond ® Fire-Shield ® Gypsum Board (Type X) fastened to 3-5/8” steel studs at 16” o.c. (20 gauge, 30 mil) Spans 8’-0” max, with ...

Design Criteria and Allowable Variances Design No. U419 September 13, 2019 Nonbearing Wall Ratings — 1, 2, 3 or 4 Hr (See Items 4 & 5 through 5K) * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.W419 (System A) 2-hour Rated Shaft Assemblies U428 U497 W419 (System B and System D) W441. 2-hour Rated Stair Shaft Assemblies U429 U498 W419 (System …Design Criteria and Allowable Variances Design No. U419 September 13, 2019 Nonbearing Wall Ratings — 1, 2, 3 or 4 Hr (See Items 4 & 5 through 5K) * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.UL U419. Interior Partition - Steel Stud (Non-Load-Bearing) Fire Rating. 1 hours. System STC. 50. System Thickness. 5.375 in. CAD/Revit & Acoustics.See General Information for Fire-resistance Ratings - ANSI/UL 263 Certified for United States. Design Criteria and Allowable Variances. See General Information for Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada. Design Criteria and Allowable Variances. Design No. D219 Restrained Assembly Ratings — 1, 1-1/2, 2 and 3 Hr

Modern Design. UL Product iQ marries the longstanding UL certification information relied upon by millions of users with the intuitive design and user-friendliness of a modern search engine. ... It combines data from many legacy UL solutions, including the Online Certification Directory, Product Spec and several iQ databases into one ...Or search by the assembly number (UL design, or Gypsum Association file number) Then click on the Search button, and your results will be displayed below. Do you have questions about Assemblies? 1-800-545-6302 ext. 5607 [email protected].

Start exploring Product iQ today! You can obtain information about the validity of a given certification by contacting the UL Solutions Customer Experience Center. Phone number: 877-854-3577- Email: CEC [at] ul [dot] com. 1:52.USG Durock® Brand Cement Board with EdgeGuard™ is preferred by many applicators as a base for directly applied finishes, tile, stone and thin brick used in building exteriors. The 12.7 mm and 15.9 mm panels are Underwriters Laboratories Inc. (UL) Classified for fire resistance, and may be used in any UL Design where Type DCB panels are listed. Fire Rating. 0.5 hours. System STC. 33. System Thickness. 4.75 in. CAD/Revit & Acoustics. Revit PDF. Visit UL U407 on the UL website. Design No. U419. BXUV.U419. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Authorities Having … 2B. Steel Studs — (As an alternate to Item 2, For use with Items 5B & 5E) Channel shaped, fabricated from min 20 MSG corrosion-protected or galv steel, 3-1/2 in. min depth, spaced a max of 16 in. OC. Studs friction-fit into floor and ceiling runners. Studs to be cut 5/8 to 3/4 in. less than assembly height. 2C. UL design I516 can span 8’-0” from wall to wall or indefinitely when used in conjunction with the hanger assembly. For 1-hour assemblies, National Gypsum developed UL design I504, which is a 1-hour horizontal assembly that consists of 3-5/8” steel studs 16” o.c. with three layers of 5/8” Type X gypsum board applied to the underside of ...

No. Fire Rating Ref. Design No. Description STC Test No. FIRE – SOUND 9 4 hr. UL V451 4 "(102 mm) I-Studs, C-T Studs or C-H Studs 24o.c. (610 mm) GA WP 7691 1" (25.4 mm) Fire-Shield Shaftliner or 1" Fire-Shield Shaftliner XP and five layers of 5/8" (15.9 mm) Fire-Shield C Wallboard applied vertically to corridor side.

Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published …

ULPRF: Get the latest ULS Group stock price and detailed information including ULPRF news, historical charts and realtime prices. Indices Commodities Currencies StocksThe UL Certification Mark on fire resistant products, systems and assemblies is relied on by code enforcement officials and buyers to provide confidence that products and systems meet regulatory and market requirements. It is a key differentiator for products within the exterior wall assembly market. The UL Evaluation Report, an additional ...UL design W419 – System A is similar to design U499 except that steel clips may be used to attach the furring channels to the studs. Clips are spaced a maximum of 24 in. OC and secured to studs with No. 8 x 1-1/2 in. minimum self-drilling S-12 steel screw through center grommet. Fiberglass Insulation. The smart choice to make spaces more comfortable and energy efficient. R-Value. The ability to resist heat flow — insulation's thermal resistance. Thermal Properties. Ability to provide thermal resistance for comfort and efficiency. Insulating for Sound. Sound absorption characteristics, helping reduce noise transmission. United announced the winners for their Her Art Here contest in which women from all over the country compete for the chance to design the livery of two Boeing 757s. Today United an... National Gypsum Purple Book - Fire-Rated Assemblies in Commercial Construction - BuildSite. This pdf provides detailed information and illustrations of various fire-rated assemblies for walls, floors, ceilings and roofs using National Gypsum products. Learn how to select the best solutions for your projects and comply with building codes and standards. UL Designs & Thicknesses for CAFCO BLAZESHIELD Isolatek’s passive fireproofing materials for the commercial and construction industry. (973) 347-1200 Select languageThe UL Prospector materials database helps you find plastics, chemicals and ingredients for your next formulation and product development challenge. Product formulators, engineers, and developers can locate technical data on hundreds of thousands of products in one easy-to-use search engine. Find materials, technical information and suppliers ...Use UL design W419 for 1- through 4-hour shaftwall systems, or UL design V497 for 1- and 2-hour assemblies using Type X. gypsum board on one side of minimum 3 " steel studs. These are all vertical assemblies designed to restrict the spread of fire in which continuity is maintained. Standard Specification for Perlite Loose Fill Insulation, ASTM ...6 CGC Fire-Resistant Assemblies Test Certification Test Conditions and Fire and sound tested assemblies listed in this Selector are based on characteristics, properties and performance Certification of materials and systems obtained under controlled test conditions as set forth in the appropriate ULC and ASTM Standards in effect at the time of test. …

6. Suggested Hilti products (ex. FS-One Max Firestop Sealant, CFS-BL Firestop Blocks) Also, please attach any pictures or sketches of your condition for clarity when submitting your request form to [email protected]. firestopping, joint, gypsum. W1_en_engineering_judgement_request_form_82019.pdf1.87 MB.UL U419. Interior Partition - Steel Stud (Non-Load-Bearing) Fire Rating. 1 hours. System STC. 49. System Thickness. 136.5 mm. CAD/Revit & Acoustics.2B. Steel Studs — (As an alternate to Item 2, For use with Items 5B & 5E) Channel shaped, fabricated from min 20 MSG corrosion-protected or galv steel, 3-1/2 in. min depth, spaced a max of 16 in. OC. Studs friction-fit into floor and ceiling runners. Studs to be cut 5/8 to 3/4 in. less than assembly height. 2C.Design No. V438 September 23, 2020 Nonbearing Wall Ratings - 1, 2, 3 or 4 Hr (See Items 4 & 5) * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. 1.Instagram:https://instagram. gore r34traffic on lie eastboundgood morning sunday african american imagesrgt 85 twitter Design Studio Design Studio. Wall Assemblies; Floor-Ceiling Assemblies; Roof-Ceiling Assemblies; Design Details; Shaft Wall Limiting Heights & Spans; Competitor Comparison Tool; USG Sustainability Tool; USG Ceiling Technix™ Virtual Acoustics Experience™ (VAE) USG Assembly Builder™ All Design Studio2B. Steel Studs — (As an alternate to Item 2, For use with Items 5B & 5E) Channel shaped, fabricated from min 20 MSG corrosion-protected or galv steel, 3-1/2 in. min depth, … disney retelling of a chinese folk legend crossword cluenapoleon.movie showtimes near regal azalea square and rpx Design No. U419 August 05, 2020 ... * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as …Refer to the UL Evaluation Report UL ER R3501 for more information and UL design W419. Do you have a summary list of all UL assemblies for construction like a table of … 1 30pm cst to pst data collection could be adopted at other centres to ul- timately enable us to gather larger volumes of data and therefore compare different.No. Fire Rating Ref. Design No. Description STC Test No. FIRE – SOUND 9 4 hr. UL V451 4 "(102 mm) I-Studs, C-T Studs or C-H Studs 24o.c. (610 mm) GA WP 7691 1" (25.4 mm) Fire-Shield Shaftliner or 1" Fire-Shield Shaftliner XP and five layers of 5/8" (15.9 mm) Fire-Shield C Wallboard applied vertically to corridor side.